Passivhaus Affiliate

Hayman House Certified

A recently certified Passivhaus new build in Gresford, North Wales provides its occupants a comfortable retirement home. The detached project with a TFA of 187m2 is built from solid concrete block and external wall insulation (EWI) and took just over a year to complete in August 2016. 

This was the first Passivhaus project for EcoVert, however, the principles had previously been applied to several other projects. The use of Warmcel to insulate the roof, made that element of the project particularly quick and straightforward.

Hayman House shading Hayman House

Performance

Thermal Energy demand (≤15kWh/m2.yr)                   14

Thermal Energy load (≤10W/m2)                                 10

Primary E demand (≤120kWh/m2.yr)                           103

Actual n50 ACH@50pascals (≤0.6ach@50pascals)     0.4

Hayman House interior

 

Hayman House interior  

 

Key Team

Client: Private

Architect: Simmonds Mills

Main Contractor: EcoVert

M&E and Environmental Consultants: Alan Clarke, Green Building Store, Tim Martel

Structural Engineer: BJSE

Certifier: Mead Architecture & Design Ltd

17th January 2017